General Specifications |
|
|
Flow Range |
|
|
Model |
: |
LS5676-2OOA |
Nominal Size (mm) |
: |
50 |
Flange Rating |
: |
JIS 10K RF |
Flow Range , L/h |
|
|
Kerosene |
: |
2000 to 20000 |
(Above 0.8mPa•s to 2mPa•s) |
|
|
Gas Oil (Heavy oil A) |
: |
1400 to 24000 |
(Above 2mPa•s to 5mPa•s) |
|
|
Heavy Oil |
: |
900 to 24000 |
(Above 5mPa•s to 200mPa•s) |
|
|
|
|
|
Meter Body |
|
|
Acceptable flulds |
: |
Kerosene,Light oil,Heavy Oil (Not serviceable with gasoline) |
Operating temp . Range (fluid temp.) |
: |
0 to 120⁰C |
Max.operating pressure |
: |
1.18MPa |
Linearity |
: |
±0.35% of RD |
Material |
|
|
Body |
: |
FC250 |
Rotors |
: |
Special resin |
Flow direction |
: |
Right → Left (standard),Left → right,bottom → top,top → bottom |
Coating color |
: |
Orange : Munsell 2.5 YR 6/13 |
|
|
|
Mechanical Register Specifications |
|
|
Model |
: |
LS5676 |
Functions |
: |
Cumulative counter with dial-and-pointer,6 digits number wheels |
Display |
|
|
One pointer rev |
: |
10 L |
Resolution |
: |
0.1L |
Counter capacity |
: |
9,999,999.9L |
Output Pulse |
: |
See next section |
Operating Temp Range |
: |
-10 to +60⁰C |
Construction |
: |
Waterproof conforming to IP 65 (weathertight) |
Material |
: |
Resin/Alumunium die casting |
Finish (houshing) |
: |
Munsell 4.9 PB4.0/13.9 (Color of molding) |
|
|
|
Factored Pulse generator in Mechanical Register (optional) |
Item |
: |
MR sensor |
Type of output pulse |
: |
Voltage pulse/open collector |
Number of pulses (per pointer rev.) |
: |
10 P |
Pulse Width |
: |
1 ms min |
Duty factor |
: |
─ |
Output Signal Levels |
: |
Voltage pulse ON:6.5V min OFF : 1 V max |
|
|
Open Collector ON:1V max |
Max.Operatiing Current |
: |
30mA |
Max.Operating Voltage |
: |
40V DC (OPEN COLLECTOR) |
Contact Bounce |
: |
─ |
Life |
: |
─ |
Signal Cable |
: |
Vinyl-insulated,4-conductor,shielded (core wire 0.5mm²,4 to 10mm in O.D) |
Transmission Distance |
: |
1 Kilometer max.(using a CVVS cable 1.25 to 2.0mm²) |
Power |
: |
12 to 24VDC ±10% |
Current Drain |
: |
20mA max |
|
|
|
Item |
: |
Reed switch |
Type of output pulse |
: |
Contact-closure pulse |
Number of pulses (per pointer rev.) |
: |
1 P |
Pulse Width |
: |
─ |
Duty factor |
: |
40/60 to 60/40 |
Output Signal Levels |
: |
─ |
Max.Operatiing Current |
: |
60mA (200Ω protective resistor provided) |
Max.Operating Voltage |
: |
125V AC,50V DC |
Contact Bounce |
: |
0.5ms max |
Life |
: |
5 x 10⁷ cycles off operating (with resistive load at 12V DC,10mA) |
Signal Cable |
: |
Vinyl-insulated,4-conductor,shielded (core wire 0.5mm²,4 to 10mm in O.D) |
Transmission Distance |
: |
1 Kilometer max.(using a CVVS cable 1.25 to 2.0mm²) |
Power |
: |
─ |
Current Drain |
: |
─ |
|
|
|
Mechanical Register Pulse Output |
|
|
Model |
: |
LS5676-2OOA |
Nominal Size (mm) |
: |
50 |
MR Sensor |
|
|
Pulse Units |
: |
1 L/P |
Pulse Units at Max Flow Rate |
: |
6.7 Hz |
Reed Switch |
|
|
Output Freq |
: |
10 L/P |
Pulse Units Output Freq |
: |
0.67 Hz |
at max Flow Rate |
|
|
Max Flow Rate (L/h) |
: |
24000 |